Glossary

The vocabulary, without the jargon.

Short, plain definitions of the terms that come up when talking about low-field, portable and open MRI.

A–Z

Terms.

Low-field MRI
MRI performed at a lower magnetic flux density than the 1.5T and 3T systems that dominate hospital imaging. In practice, low-field usually means anything below roughly 1T, and ultra-low-field below 0.1T.
Field strength
The magnetic flux density of the main field, measured in tesla (T). Signal-to-noise ratio scales roughly with field strength, which is why higher field was pursued for decades.
Permanent magnet
A magnet that produces its field without an electrical current or cryogenic cooling — typically NdFeB or SmCo. It cannot be switched off, but it removes liquid helium, the quench risk and the compressor.
Halbach array
An arrangement of permanent magnets in a ring whose field is strong inside and weak outside. It allows a compact, lightweight magnet with a usable bore.
Open magnet
A geometry that leaves the patient space accessible rather than fully enclosed — C-type and H-type designs are common. Useful for claustrophobic patients, interventional access and standing or seated scanning.
SNR (signal-to-noise ratio)
How much real signal there is compared with random noise. The central constraint in low-field imaging, and the reason reconstruction algorithms matter so much.
EMI (electromagnetic interference)
External noise from mains wiring, motors, lifts and broadcast sources that corrupts the signal. A shielded room is the traditional answer.
EMI cancellation
Measuring ambient noise with dedicated sensing coils and subtracting it in real time using deep learning — the reason a system can image in an ordinary room.
Shielded room
A copper or steel enclosure that blocks external electromagnetic noise. Costly to build on site and impossible to move — which is why here it ships as a modular enclosure instead of being built.
Larmor frequency
The precession frequency of a nucleus in a magnetic field, proportional to field strength. It sets the operating frequency of the system and the design of its coils.
T1 / T2 relaxation
The time constants that describe how nuclear magnetisation recovers and decays. Image contrast comes from the difference between these values across tissues.
Compressed sensing
A reconstruction approach that recovers an image from fewer measurements than classical theory requires, by exploiting the fact that images are sparse in some representation.
Parallel imaging
Using multiple receiver coils to acquire less data while keeping the image — the coil geometry supplies the missing spatial information.
Metal artifact
Distortion around implants and prostheses. It scales with field strength, so implants are noticeably less troublesome at low field.
Standing / weight-bearing MRI
Scanning a patient upright and load-bearing, so that the anatomy is imaged in the position that produces the symptoms.
Point-of-care imaging
Imaging brought to where the patient already is — the bedside, the ward, the operating theatre — rather than moving the patient to the scanner.